Knowledge of cold storage maintenance
Release time:2018-6-8 11:13:35      Number of clicks:1169
1. Operating unit: always observe the oil surface and oil return of the compressor and the cleanliness of the oil, and find that the oil dirty or oil surface drop should be solved timely, so as not to cause bad lubrication.
2. For the air cooling unit, the air cooler shall be cleaned regularly to keep it in a good heat exchange state. For water cooling unit: always check the turbidity degree of cooling water, such as too dirty cooling water, should be replaced. Check the water supply system for bubbling, bubbling, dripping and leakage problems. Whether the pump works normally, whether the valve switch is effective, whether the cooling tower, whether the fan is normal. For cold air units: frequently check condenser scaling problems, to timely remove scale.
3. For the evaporator of the air cooler: it is necessary to check the defrosting frequently. Whether the defrosting is timely and effective will affect the cooling effect and lead to the return of the refrigeration system.
4. Observe the running state of the compressor frequently and check the exhaust temperature. During the operation of the compressor in the new season, pay special attention to the running state of the system and adjust the system's liquid supply and condensing temperature in time.
5. Listen carefully to the operation of the compressor, cooling tower, water pump or condenser fan, and check the vibration of the compressor, exhaust pipe and ground feet.
6, the compressor maintenance: early internal system cleanliness is poorer, running after 30 days to change a frozen oil and filter drier, change again after running for half a year (according to the actual situation and decide). For systems with high cleanliness, it is necessary to replace the refrigerated oil and the dry filter once after half a year of operation, which will depend on the situation in the future.
7. Pay attention to the oil surface of the oil mirror of the cold storage compressor within the scope specified by the oil mirror. If the cold storage compressor is short of oil, it will cause a chain failure of dead, spindle and burning motor.
8. In the refrigeration system, it is necessary to install voltage missing phase, overload, current protection, delay protection, and protection of the sensitivity and quality of functional electrical components, which directly affect the life of the compressor. Refrigeration system installation and debugging, according to the temperature controller, pressure controller make the compressor within an hour's drive less than 6 times, stop running in more than five minutes at a time, stop time not less than 3 minutes at a time.
9, no non-condensable gas cooling system (air or nitrogen), not more than 2%, its volume vacuum vacuum operation on its own, use the vacuum pump (vent valve) from the system of high pressure end time, time more than 20 minutes.
10. The refrigeration circulation system must be strictly dry. Especially when the seamless steel tube is used as evaporator, no rust is allowed, no residual organic compounds, metal impurities, cleaning agents, acids and water are allowed.
11. After the operation of the refrigeration system, pay attention to the level of oil surface in a timely manner. The refrigerated oil should be replaced one month after the first operation.
12. The reliability and sensitivity of electrical design control elements, temperature and pressure controllers are reliable to reduce compressor failure.
13. Check the power voltage and whether the ambient temperature is within the specified range.
14. When the compressor is stopped for a long time, the refrigerant should be returned to the reservoir and the exhaust stop valve should be closed.

The last one:The difference between a medicine freezer and a food freezer
Next:Common troubleshooting methods for refrigeration compressors

Return list

Recommended for you

  • Mobile web site

  • The official WeChat

版權(quán)所有: 江蘇利邦機電設(shè)備有限公司 Copyright ? 2018 蘇ICP備18027510號-1

主站蜘蛛池模板: 日本久久久久亚洲中字幕| 久久99热只有频精品6国语| 国产高潮流白浆视频| 无码中文字幕在线播放2| 久久亚洲精品国产亚洲老地址| 国产国拍亚洲精品永久软件| 亚洲欧美日韩成人一区| 亚洲精品久久区二区三区蜜桃臀| 亚洲精品国产肉丝袜久久| 精品国产久九九| 日本黄漫动漫在线观看视频| 特黄 做受又硬又粗又大视频| 国产人妻精品无码av在线| 国产成人av一区二区三区在线观看| 国产精品视频免费一区二区| 爽爽影院免费观看| 人人妻人人超人人| 亚洲精品无码专区久久| 亚洲欧美精品伊人久久| 国产成人无码av大片大片在线观看| 丰满熟妇被猛烈进入高清片| 亚洲熟妇真实自拍另类| 亚洲国产aⅴ精品一区二区的游戏| 国产成人精品日本亚洲专区61| 久久www免费人成—看片| 文中字幕一区二区三区视频播放| 一本色道久久东京热| 色偷一区国产精品| .精品久久久麻豆国产精品| 国产av一区二区精品久久凹凸| 夜夜躁很很躁日日躁麻豆| 日本丰满护士爆乳xxxx| 激情五月综合色婷婷一区二区 | 亚洲无线观看国产精品| 玩弄少妇人妻中文字幕| 亚洲伊人久久综合网站| 欧美人与物videos另类| 人妻熟女久久久久久久| 熟女俱乐部五十路六十路av| 欧美激情一区二区三区aa片| 亚洲成a人片在线不卡一二三区 |